Safety Information

This section outlines essential safety precautions for operating the spa. Always keep the unit dry use approved cords avoid contact with water during maintenance. Maintain water temperature 104F, and ensure grounding to prevent shock. Follow all local codes. Trained; emergency switches accessible. Training required

Operating Precautions

Before each use, verify that the spa is level and that the water level is within the manufacturer’s recommended range. A properly leveled unit ensures that jets operate efficiently and that the drain valve functions correctly. If the spa sits on an uneven surface, use shims only for small adjustments; large Grandee models must rest on a 4‑inch (10.1 cm) concrete pad or a structurally engineered deck, never on shims. Over‑filling can cause water to spill over the rim, creating a slip hazard and potentially damaging the electrical system. Always keep the cover closed when the spa is not in use to prevent accidental falls and to maintain temperature. Children and pets should never be left unattended in or near the spa. If a child or pet falls in, immediately turn off the power at the main breaker, lift the cover, and remove the animal. Do not use the spa if the water temperature exceeds 104 °F (40 °C), as this can lead to heat‑related illness. Avoid alcohol or drug use before or during spa operation, as these substances impair judgment and increase the risk of injury. Keep all electrical cords and outlets dry and in good condition; never use damaged cords; If the spa is located near a water source, ensure that the plumbing is secure and that the drain valve is fully open before filling. Inspect the unit for cracks or damage before each use; any visible damage should be repaired before the spa is filled. Keep the spa area free of debris and ensure that the surrounding floor is non‑slip. Do not allow the spa to be used during a thunderstorm or when lightning is present; disconnect the power and cover the unit. When refilling, use only potable water and avoid adding chemicals that are not approved for spa use. Follow the manufacturer’s recommended cleaning and maintenance schedule to keep the jets and filtration system operating safely. Finally, train all users on proper entry and exit procedures and on how to respond in case of an emergency. Additionally, before each session, check that the cover latch is secure, that the filter cartridge is free of debris, and that the drain valve is not leaking. If any component shows signs of wear or malfunction, stop using the spa and consult a qualified technician. The spa’s water should be tested for pH and chlorine levels at least once a week, and the water should be replaced or treated as needed to maintain a safe and comfortable environment for all users.

Electrical Safety Guidelines

The spa’s power supply should be connected to a dedicated, grounded circuit with a GFCI outlet that trips within 20 ms of a fault to prevent shock. Use only the supplied, UL‑listed extension cords if the spa is not directly wired; cords must be rated for outdoor use, minimum 12‑AWG, and free of kinks or cuts. Inspect cords daily for wear and replace any damaged cord immediately. All wiring connections must be tightened and insulated; loose connections can cause arcing and fire. Never use the spa during a storm or when lightning is present; disconnect the power at the main breaker and cover the unit. When servicing the spa, first turn off the main breaker, then disconnect the power at the spa’s internal disconnect. Never touch the water or any metal parts while the spa is powered. The spa’s water temperature should not exceed 104 °F (40 °C). In case of a power surge, the spa’s surge protector will divert excess voltage; however, it is recommended to use a dedicated surge protector for added safety. Finally, schedule annual inspections by a licensed electrician to verify that all grounding, bonding, and GFCI requirements remain compliant. Proper electrical maintenance ensures the spa operates safely and extends its lifespan. The grounding electrode should be a 6‑inch copper rod driven into the earth and bonded to the spa’s metal frame to provide a low‑resistance path for fault currents. All metal plumbing components must be bonded to the grounding system to prevent stray currents. The control board shuts down automatically if it detects a fault current above 30 mA. Test GFCI!!

Installation Requirements

Place the Grandee on a level, 4‑inch concrete pad or engineered deck. No shimming allowed. Ensure the pad thickness meets 10.1 cm and is structurally sound. Verify the pad is level within 1/8 inch. Follow manual

Leveling and Shimming Guidelines

For optimal performance and safety, the Hot Spring Grandee must rest on a perfectly level surface. The manufacturer specifies a minimum pad thickness of 4 inches (10.1 cm) or an equivalent structurally engineered deck. The pad must be free of cracks, voids, and any irregularities that could compromise the spa’s structural integrity. Prior to installation, use a precision level to verify that the pad is level within ±1/8 inch across all four corners. Any deviation beyond this tolerance can lead to uneven wear, improper drainage, and potential electrical hazards.

In the event that the existing foundation cannot provide the required flatness, the use of shims is strictly prohibited for Grandee models. Instead, the pad should be replaced or reinforced to meet the specified thickness and level criteria. If shimming is attempted, the spa’s internal plumbing may fail to drain fully, leading to water accumulation, corrosion, and a higher risk of electrical shock. The manufacturer’s guidelines emphasize that shimming can compromise the warranty and void service agreements.

To achieve the correct level, follow these steps:

  • Inspect the pad surface for any depressions or protrusions.
  • Use a high‑accuracy laser level or spirit level to measure each corner.
  • Adjust the pad by adding or removing concrete as needed, ensuring the final thickness remains 4 inches.
  • Re‑check the level after adjustments and before placing the spa.
  • Secure the spa with the provided mounting brackets, ensuring all bolts are tightened to the manufacturer’s torque specifications.

Adhering to these leveling and shimming guidelines guarantees proper drainage, extends the spa’s lifespan, and maintains compliance with safety regulations. Failure to comply can result in operational issues, safety hazards, and potential damage to the spa’s components.

When preparing the site, consider the following additional recommendations: ensure the pad is located on a stable, non‑sagging foundation; use a concrete mix with a compressive strength of at least 3,500 psi; allow the concrete to cure for a minimum of 28 days before installing the spa; and verify that the pad’s surface is smooth to prevent uneven pressure distribution. Proper drainage channels should be incorporated around the pad to direct any runoff away from the spa’s electrical connections. By following these detailed procedures, installers can guarantee that the Hot Spring Grandee operates safely, efficiently, and reliably for many years of enjoyment.

Concrete Pad Specifications

For the Hot Spring Grandee, the manufacturer mandates a concrete pad that is at least 4 inches (10.1 cm) thick and fully level. The pad must be constructed from a high‑strength mix with a compressive strength of no less than 3,500 psi to support the spa’s weight and prevent settlement. A smooth, flat surface is essential; any voids or irregularities can lead to uneven load distribution and compromise the spa’s structural integrity. The pad should be poured in a single continuous slab, with a minimum thickness of 4 inches across the entire footprint, and should be cured for at least 28 days before the spa is placed. During curing, keep the slab moist and protected from direct sunlight or wind to avoid cracking.

Edge reinforcement is required: embed steel rebar or wire mesh in the bottom layer of the slab, spaced no more than 12 inches apart, to resist tensile forces and provide additional stability. The pad’s perimeter must be sealed with a high‑quality waterproofing membrane to prevent water infiltration that could damage the concrete or the spa’s electrical components. A drainage layer of gravel or crushed stone should be placed beneath the slab, sloping away from the spa to facilitate runoff. The pad’s surface should be leveled to within ±1/8 inch across all four corners; use a precision laser level or spirit level to verify compliance.

Installation must follow local building codes and any homeowner association requirements. The pad should be anchored to the underlying foundation with concrete anchors or expansion bolts, ensuring the spa remains stationary during operation. Finally, verify that the pad’s load capacity exceeds the spa’s maximum weight, including water, users, and accessories. Proper adherence to these concrete pad specifications guarantees safe operation, prevents premature wear, and protects the spa’s warranty and performance.

Spa Specifications

The Grandee model offers 8‑person capacity, 4.5 ft × 7.5 ft footprint, 5.5 ft height. It features 12 high‑pressure jets, 2 massage jets, and a 3‑zone temperature control. The unit weighs 1,200 lb and requires a 4‑in concrete pad. Dimensions: 4.5 ft × 7.5 ft; Height: 5.5 ft; 3,500 gal.

Dimensions and Capacity

The Hot Springs Grandee is engineered for comfort, featuring a footprint 4.5 ft (1.37 m) width 7.5 ft (2.29 m) length morein. The overall height from the floor to the top of the shell is 5.5 ft (1.68 m), providing ample headroom for taller users. The unit’s interior volume is approximately 3,500 gal (13,250 L), which supports a maximum user capacity of eight adults or a combination of adults and children. Each seat is padded with a 2‑inch (5 cm) foam layer and reinforced with a steel frame to ensure durability and stability during use. The spa’s weight, including the shell, jets, and plumbing, is roughly 1,200 lb (544 kg), requiring a solid foundation. For optimal performance, the Grandee must be installed on a 4‑inch (10 cm) thick concrete pad or a structurally engineered deck that can support the load and maintain level. The spa’s water capacity is measured at 3,500 gal when the water level is set at the 3‑inch (7.6 cm) mark above the lowest jet. This volume allows for efficient heating and filtration cycles while maintaining a comfortable temperature range of 100–104 °F (38–40 °C). The seating arrangement includes four forward seats and four rear seats, each positioned to allow easy access to the jets and controls. The design also incorporates a 12‑jet system, with six high‑pressure jets and six massage jets, each calibrated to deliver a balanced hydrotherapy experience. The Grandee’s dimensions and capacity are optimized for both residential and commercial settings, ensuring that users can enjoy a full‑body soak without compromising safety or comfort.

Jet Configuration and Controls

The Hot Springs Grandee features a sophisticated jet system designed for optimal hydrotherapy. Spa is equipped with 12 strategically placed jets: six jets located at the front and rear corners for a massage, and six jets positioned along the side panels to provide targeted relief for the back. Each jet is individually adjustable, allowing users to customize pressure settings from low to high. Control panel, located on the front wall, offers a user‑friendly interface with a digital display, temperature readout, and a dedicated jet control knob for each zone. Users can select preset programs such as “Relax,” “Therapeutic,” or “Custom,” which automatically adjust jet intensity, temperature, and circulation speed. The jets feature a unique pulsation mode that simulates a rhythmic massage, enhancing circulation and muscle recovery. For safety, system includes an automatic shut‑off feature that activates if water temperature exceeds 104°F or if the water level drops below the minimum threshold. Control panel also displays real‑time filtration status and alerts users to filter cartridge maintenance. Jet configuration is designed to work in tandem with spa’s filtration and heating systems, ensuring a consistent and safe user experience.

Each jet’s flow rate is calibrated to deliver 2.5 gallons per minute at maximum pressure, ensuring sufficient water volume for effective massage while maintaining energy. Enjoy.

Drain, Clean, and Refill Procedures

Drain the spa by opening the drain valve, allowing water to exit completely. Clean filters, remove debris, and rinse. Refill with fresh, balanced water to the recommended level. Test jets, verify circulation, and adjust chemicals as needed. Maintain proper pH daily.

Scheduled Maintenance Schedule

Follow the manufacturer’s recommended maintenance interval to keep the Grandee spa operating safely and efficiently. The schedule below is based on the Hot Spring Grandee owner’s manual and industry best practices.

  • Weekly: Inspect the filter cartridge for visible debris. Rinse with a mild, non‑ionic detergent and re‑install. Test water temperature and adjust to 104°F. Verify that all jets are and circulation pump runs.
  • Bi‑Weekly: Perform a full water change on the spa. Drain to the lowest point, clean interior surfaces with a spa‑safe cleaner, and refill with fresh, balanced water. Re‑balance pH (7.2–7.4) and alkalinity (80–120 ppm) before operating.
  • Monthly: Check electrical connections for corrosion or loose contacts. Inspect control panel for proper operation of safety shut‑off and emergency stop. Clean filter housing and replace cartridge if it shows signs of wear or clogging.
  • Quarterly: Conduct thorough inspection of spa’s structural integrity. Verify concrete pad remains level and shims secure. Test pressure sensor and ensure jet system responds correctly to control inputs. Check all bolts for tightness.
  • Annually: Schedule professional service appointment. Technician will perform chemical analysis, pump and motor inspection, and review of spa’s mechanical and electrical components. Replace worn parts and update firmware if applicable.

Adhering to this schedule will extend the life of your Grandee spa, maintain water quality, and reduce the risk of equipment failure or safety hazards!!!

Water Filtration System Overview

The Hot Spring Grandee spa employs a dual‑stage filtration system that keeps water crystal‑clear and protects internal plumbing. The primary filter cartridge, made of high‑density polyester media, captures particles as small as 10 µm. A secondary cartridge with finer media (2–5 µm) removes finer debris and keeps jets clog‑free. The pump forces water through the primary filter, then the secondary filter, before returning to the spa. The flow rate is set to 0.5 gpm per square foot of spa surface area, ensuring adequate turnover while minimizing energy use. A pressure‑sensing valve shuts the pump off if pressure exceeds 15 psi, preventing over‑pressurization of filter housings. Weekly maintenance involves removing the cartridge, rinsing with a spa‑safe detergent, and inspecting for wear or clogging. Replace the cartridge if it shows discoloration or if flow drops below 80 % of rated capacity. For the secondary filter, rinse with a 1 % bleach solution every two weeks to control biofilm. Water chemistry is critical: keep pH 7.2–7.4, alkalinity 80–120 ppm, chlorine or bromine 1.0–3.0 ppm, and calcium hardness 200–400 ppm to avoid scaling. When draining for maintenance, clean filter housings with a non‑ionic cleaner, refill, and run the pump 30 minutes to saturate filters. The housings are reinforced ABS plastic with gasket seals and a built‑in air‑lock vent. If water clarity drops or the pump makes noise, check for loose screws or cracked gaskets; tighten with a 10 mm wrench and replace as needed. Common issues include cartridge clogging (reduced flow, high pressure). If pressure spikes above 12 psi, backwash by reversing the pump for 30 seconds; if pressure remains high, replace the cartridge. Biofilm on the secondary filter can be mitigated with a bleach rinse every two weeks. Primary cartridges last 6–8 months; secondary up to 12 months under normal use. Keep a maintenance log of cartridge dates, water chemistry, and filter performance to anticipate changes and avoid downtime. Consistent care prolongs filter life and keeps water pristine.

Water Chemistry and Balancing

Maintaining proper water chemistry is essential for a safe, comfortable, and long‑lasting Hot Spring Grandee spa experience. Test the water every 2–3 days during heavy use and weekly during normal use with a calibrated test kit. The target ranges are: pH 7.2–7.4, total alkalinity 80–120 ppm, free chlorine or bromine 1.0–3.0 ppm, and calcium hardness 200–400 ppm. Adjust pH first; use a pH‑up (sodium carbonate) or pH‑down (sodium bisulfate) solution and retest until the desired level is reached. Next, balance alkalinity by adding an alkalinity increaser or decreaser, always allowing the water to circulate for 30 minutes before retesting. Calcium hardness is corrected by adding a calcium hardness increaser; if hardness is too high, a calcium reducer or a partial water change may be necessary. When adding chemicals, pour slowly into the spa’s circulation system to distribute evenly. After each adjustment, run the jets for 15 minutes to ensure thorough mixing. Keep a log of all additions, dates, and test results for future reference. If the water becomes cloudy or the filter clogs quickly, check for pH drift or high calcium levels and correct promptly. Proper balancing reduces scale, prevents corrosion, and keeps the spa’s filtration system operating efficiently. Shock treatment is recommended once a week or after heavy use; use a shock to avoid irritation. Temperature fluctuations can affect sanitizer efficacy; maintain 100–104 °F to keep chlorine or bromine stable. Use a calcium chloride solution to raise hardness if the water is too soft, as soft water can corrode metal parts. Conversely, if hardness is too high, perform a partial water change of 25–30 % and add a calcium reducer. Regularly inspect the filter cartridge for biofilm; clean with a spa‑safe detergent and rinse thoroughly. By following these guidelines, the spa will remain clear, odor‑free, and safe for all users. Enjoy responsibly. Always. OK